EXOLINE AQUA STOP C+C
Factory-premixed waterproof and frost-resistant concrete
Exoline® Aqua Stop C+C
Article number:
EXO-ASCC-006-25KG
Product type:
Ready-mixed products
Product description:
Antifreeze and waterproof finished concrete
Read More
Ready to use, factory pre-mixed, hydraulic bonded, universal, hydrophobic, indoor and outdoor waterproof, antifreeze finished concrete.
Packaging:
25 kg plastic bucket
Evaluation:
Price:
Benefits offered by Exoline® product line:
Their important feature is that the product can use other systems, such as lubricated insulation, foils, liquid foil, heavy plates and other technological solutions that increase the risk of construction-costs and time.It enhances the efficiency of insulation through its insulation and water repellent properties, and it is advisable to use in all cases where the water closure of the building is important and the simple, fast and durable solution is the goal.
Exoline® Aqua Stop C+C composite concrete has a highly waterproof, water -repellent (hydrophobic) properties and is well suited for waterproofing and antifreeze after its mixing with water.
Area of use:
Old and newly built, cellars, cellars, sockets, sidewalks, lightweight slabs, balconies, wet roofs - green roofs, garages, tunnels, for construction and renovation.
For general concrete, assembly concrete, floor heating concrete concrete, thin sockets, shutters, retaining walls, bases, slabs, wreaths, pillars, stairs, weather -exposed surfaces, spatial concrete waterproof and antifreeze.
Old dusty, worn, cracked, possibly deficient concrete, sidewalk, garage substrate, stairs, etc. .... from 5 mm of material thickness, but at least 2 cm thick to achieve good waterproofing.The dimensioning of the thickness also depends on the amount of later load.In the case of industrial use, where high use forklift, agricultural machinery, trucks, etc.After the proper stratification (gravel, rammed ground, crusher), ironing can be made by ironing at least 15 cm.
If new concrete surfaces are made, the upper abrasive layer is sufficient.
Particularly suitable for replacing the resin in cases where the surface would be exposed to extremely high temperatures.The additive used reduces the surface water uptake.
It is also suitable for lowering the substrates of the substrate equalizer to reduce the thickness of
Technical /Material Technology Data:
Material composition: | Cement, sand, lime hydrate, rheological additives and property enhancement additives, pre -mixed dry mortar.It does not contain any asbestos or other mineral fibers, so there is no fine silicogenic quartz powder that is harmful to health. |
Ingredients: | One-component |
Status: | By |
Color: | Gray |
Disqualification for the transport of goods: | Not a dangerous commodity |
Regulation for Hazardous Materials: | Irritant contains cement |
More information: | See "Safety Instructions" chapter |
Storage: | In a dry place, stored protected from weather effects at least 12 months.It should not be stored permanently above +30 ° C.The packaging that has begun should be carefully closed. |
Packaging: | 500kg, 1000kg Big Bag bag and 25kg plastic bucket / bag |
Surface preparation:
The surface, solid, plane, load bearer, shrink-free, crack free, clean, dust-tar-oil-wax-free.It cannot have anti -stick residues.
The surface of the old concrete must be cleaned.The loose, mild surface should be engraved all the way to the intact concrete.The concrete that is still intact should be rumble and washed.The old coatings that are not firmly adherent must be removed.
The training of dilatations must be carried out in accordance with the current construction standards and the dilation of the existing building.
Depending on the absorbent capacity of the base area, use a deep base.
Work:
To the prescribed mixing water amount, the bucket/bag contents gradually add the concrete to a low -speed concrete mixer mixed with a cold, piped water.The mixing time is at least 5 minutes.
When repairing old powdered concrete, apply a thin layer deep into the cleaned surface to help stick between the two surfaces.
Only the material should be mixed as the approx.We can use it within a 40 -minute work period.
The material can be used with traditional masonry tools.During the application, care should be taken to clean, no foreign contamination (cigarette butts, matches, mud, etc.) should be included in the material
Working temperature:
Depending on the weather above 25 ° C, spraying (watering) is recommended every 2-3 hours after concrete processing.Sudden dehydration can greatly worsen the quality of the product.Recommended application period between + 5 ° C and + 25 ° C.+20 ° C, humid, wet weather/ area The aftercare of the plaster is not required or partially necessary.
Other information:
The concrete must be well mixed after a longer period of time.
Tool cleaning:
Before the concrete is solidified with water.
Safety Regulations:
In the case of work with our products, the most important physical, safety, toxicology and ecological data can be found on the safety data sheet for products.Provisions for hazardous substances must be observed.
Expiration date:
It can be stored in an unopened original pack for 12 months.
Manufacturer Warranty:
For proper mixing and use - 10 years!
Product Features - Benefits:
Our products are compatible with all cement -based construction products on the market!
It consists of or from natural (organic) ingredients (ingredients).contain!
Easy and quick to work!
Binding and fluid!
Shorter Elimination Time, so meaningful work can start sooner!
Frost - acid - alkaline and oil standing!
It is very resistant to strong temperature fluctuations!
It improves the durability, quality parameters of concrete and improves the thermal insulation of concrete! It makes multi -component work -phase waterproofing materials and related construction fees unnecessary!
It can save significant construction costs as it replaces the insulating systems known so far almost everywhere!
The life content of the exoline® surface is multiplied!
Provides excellent abrasion resistance!
Less cement use (eg C22 - Exoline® mixed with C28 Strength!)
Live workforce, tools, material - water, cement - decrease, higher quality guaranteed!
Exoline® mixed in concrete does not require any other post -insulation or insulation after concreting, as the insulation is included in the concrete itself!
25C - does not require or only partially requires after -treatment!
(Illustrations in use)